hw/scsi/mptsas: Avoid silent integer truncation in MPI_FUNC_IOC_INIT
For the MaxDevices 8-bit field of the request / response structures of the MPI_FUNCTION_IOC_INIT command, the 0x00 value means "max 256 devices". This is not a problem because when max_devices=256, its value (0x100), being casted to a uint8_t, is truncated to 0x00. However Coverity complains for an "Overflowed constant". Fix by re-using the request fields in the response, since they are not modified and use the same types. Fix: Coverity 1547736 (Overflowed constant) Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org> Reviewed-by: Peter Maydell <peter.maydell@linaro.org> Message-Id: <20250811095550.93655-1-philmd@linaro.org>
This commit is contained in:
parent
c5ade4f9d2
commit
7baa9c39fc
1 changed files with 3 additions and 3 deletions
|
|
@ -579,11 +579,11 @@ static void mptsas_process_ioc_init(MPTSASState *s, MPIMsgIOCInit *req)
|
|||
}
|
||||
|
||||
memset(&reply, 0, sizeof(reply));
|
||||
reply.WhoInit = s->who_init;
|
||||
reply.WhoInit = req->WhoInit;
|
||||
reply.MsgLength = sizeof(reply) / 4;
|
||||
reply.Function = req->Function;
|
||||
reply.MaxDevices = s->max_devices;
|
||||
reply.MaxBuses = s->max_buses;
|
||||
reply.MaxDevices = req->MaxDevices;
|
||||
reply.MaxBuses = req->MaxBuses;
|
||||
reply.MsgContext = req->MsgContext;
|
||||
|
||||
mptsas_fix_ioc_init_reply_endianness(&reply);
|
||||
|
|
|
|||